Callaghan Innovation Research Papers

Our scientists and engineers publish papers in a range of academic journals. This database provides you access to a list of their papers.

 

Filter by: Year All | 2013 | 2014 | 2015 | 2016 | 2017 | 2018 | 2019 | 2020 

Filter by: Author

Export 35 results:
[ Author(Desc)] Title Year
Filters: Author is White, D.R.  [Clear All Filters]
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
W
Interpolation Errors in Thermistor Calibration Equations, White, D.R. , International Journal of Thermophysics, 2017, Volume 38, Issue 4, (2017)
Propagation of Uncertainty and Comparison of Interpolation Schemes, White, D.R. , International Journal of Thermophysics, 2017, Volume 38, Issue 3, (2017)
The status of Johnson noise thermometry, White, D.R., Galleano R., Actis A., Brixy H., De Groot M., Dubbeldam J., Reesink A.L., Edler F., Sakurai H., Shepard R.L., et al. , Metrologia, 1996, Volume 33, Issue 4, p.325 - 335, (1996)
In pursuit of a fit-for-purpose uncertainty guide, White, D.R. , Metrologia, 2016, Volume 53, Issue 4, p.S107 - S124, (2016)
Resistance network for verifying the accuracy of resistance bridges, White, D.R., and Williams J.M. , IEEE Transactions on Instrumentation and Measurement, 1997, Volume 46, Issue 2, p.329 - 332, (1997)
Frequency-response mismatch effects in Johnson noise thermometry, White, D.R., and Qu J.-F. , Metrologia, 2018, Volume 55, Issue 1, p.38 - 49, (2018)
Reflectometer for measuring the bidirectional reflectance of rough surfaces, White, D.R., Saunders P., Bonsey S.J., Van Ven J.D., and Edgar H. , Applied Optics, 1998, Volume 37, Issue 16, p.3450 - 3454, (1998)
Propagation of uncertainty on interpolated scales, with examples from thermometry, White, D.R., and Saunders P. , Metrologia, 2000, Volume 37, Issue 4, p.285 - 293, (2000)
Preamplifier limitations on the accuracy of Johnson noise thermometers, White, D.R., and Zimmermann E. , Metrologia, 2000, Volume 37, Issue 1, p.11 - 23, (2000)
On the choice of comparison reference values for the purpose of pair-wise comparison of laboratories, White, D.R. , CPEM Digest (Conference on Precision Electromagnetic Measurements), 2000, p.325 - 326, (2000)
The propagation of uncertainty with non-Lagrangian interpolation, White, D.R. , Metrologia, 2001, Volume 38, Issue 1, p.63 - 69, (2001)
Comment on Quinn and Mills' proposal for the uno, White, D.R., and Nicholas J.V. , Metrologia, 2001, Volume 38, Issue 4, p.369 - 371, (2001)
On the analysis of measurement comparisons, White, D.R. , Metrologia, 2004, Volume 41, Issue 3, p.122 - 131, (2004)
The propagation of uncertainty with calibration equations, White, D.R., and Saunders P. , Measurement Science and Technology, 2007, Volume 18, Issue 7, p.2157 - 2169, (2007)
A schottky-diode model of the nonlinear insulation resistance effects in SPRTs-Part 1: Theory, White, D.R., Arai M., Bittar A., and Yamazawa K. , International Journal of Thermophysics, 2007, Volume 28, Issue 6, p.1843 - 1854, (2007)
Uncertainties in the realization of the SPRT sub-ranges of the ITS-90, White, D.R., Ballico M., Del Campo D., Duris S., Filipe E., Ivanova A., Dogan A.K., Mendez-Lango E., Meyer C.W., Pavese F., et al. , International Journal of Thermophysics, 2007, Volume 28, Issue 6, p.1868 - 1881, (2007)
A graphical method for calculating reflection errors in radiation thermometry, White, D.R., and Saunders P. , International Journal of Thermophysics, 2008, Volume 29, Issue 1, p.395 - 402, (2008)
Constraints on a synthetic-noise source for Johnson noise thermometry, White, D.R., and Benz S.P. , Metrologia, 2008, Volume 45, Issue 1, p.93 - 101, (2008)
A general technique for calibrating indicating instruments, White, D.R., Clarkson M.T., Saunders P., and Yoon H.W. , Metrologia, 2008, Volume 45, Issue 2, p.199 - 210, (2008)
Measurement time and statistics for a noise thermometer with a synthetic-noise reference, White, D.R., Benz S.P., Labenski J.R., Nam S.W., Qu J.F., Rogalla H., and Tew W.L. , Metrologia, 2008, Volume 45, Issue 4, p.395 - 405, (2008)
Observations on sub-range inconsistency in the SPRT interpolations of ITS-90, White, D.R., and Strouse G.F. , Metrologia, 2009, Volume 46, Issue 1, p.101 - 108, (2009)
Wide-range electrostatic loudspeaker with a zero-free polar response, White, D.R. , AES: Journal of the Audio Engineering Society, 2009, Volume 57, Issue 10, p.822 - 831, (2009)
A thermocouple homogeneity scanner based on an open pressure-controlled water heatpipe, White, D.R., and Mason R.S. , International Journal of Thermophysics, 2010, Volume 31, Issue 8-9, p.1654 - 1662, (2010)
Improved estimates of the isotopic correction constants for the triple point of water, White, D.R., and Tew W.L. , International Journal of Thermophysics, 2010, Volume 31, Issue 8-9, p.1644 - 1653, (2010)
The hysteresis characteristics of some industrial PRTs, White, D.R., Jongenelen C.L., and Saunders P. , International Journal of Thermophysics, 2010, Volume 31, Issue 8-9, p.1676 - 1684, (2010)

Pages

Back to top